Introduction
Although low voltage cable and distribution cable have relatively low voltage, the fault’s location is more difficult than HV cable because of the larger quantity lines and bad environment. Because of common HV surge generator’s high output is over the max withstand voltage of LV cable, which is very easy to cause new faults. T8 overcomes this problem effectively. The max output is 15kV, but max impulse energy up to 900J which can protect the LV cable and make the recharge sound loud enough.
Fault location power LP15/8
|
|
DC voltage output
|
0-15 kV continuously adjustable
|
Output power
|
Peak 2000W
|
Capacitance
|
8μf
|
Max discharge energy
|
900J
|
Power supply
|
AC220V, 50Hz
|
Size
|
500×305×457(mm)
|
Weight
|
29.5kg
|
Cable fault pre-locator (TDR) WL20
|
|
Low voltage impulse launching voltage
|
30V
|
Sampling frequency
|
200MHz
|
Max ranging scope
|
100km
|
Dead zone
|
1m
|
Max resolution
|
0.4m
|
Power supply
|
Lithium battery
|
Size
|
274×218×81(mm)
|
Weight
|
3.5kg
|
Cable fault pin-pointer PP20
|
|
Precision of point positioning
|
0.1m
|
Precision of path location
|
0.1m
|
Precision of step voltage method
|
0.1m
|
Work mode |
Anti-noise mode:
Strong noise reduction mode Background suppression noise reduction mode Point location mode: Intelligent Acousto-Magnetic Time Difference Mode |
Display mode
|
Color LCD
|
Power
|
Li-battery, 12h standby
|
To be an international, standardized and sustainable corporation is our consistent pursuit. We sincerely welcome customers from home and abroad to visit our company.