Introduction
In the cable fault test, there are always faults like intermediate joint damp of insulation, water-in cable, the fault cannot be burn through by flashover. These faults generally 1~2MQ, some even tens MQ or hundreds MQ, called super-high resistance fault. When these fault occur, the methods based on impulse reflection principle cannot locate the fault effectively. LB4/60, uses mew digital location model, and combines with Wheatstone Bridge tech and constant current burn through technology, the output voltage up to 60 kV, location current 600 mA, having solved these super-high resistance faults effectively. It's the necessary instrument of cable maintenance department.
Burn through function |
Output voltage
|
0-60kV continuously adjustable
|
Short-circuit current
|
400mA
|
|
Bridge function |
Output voltage
|
0-4kV
|
Short-circuit current
|
750mA
|
|
LCD screen
|
128 x 64 (mm)
|
|
Location precision
|
±(0.2%*L+1)m
|
|
Testing range
|
1~50000m
|
|
Operating keyboard
|
One key operation
|
|
Power supply
|
220V AC±10%, 50Hz
|
|
Power
|
1kVA, generator as power supply(>1kW)
|
|
Weight
|
30kg
|
|
Size
|
300 x 460 x 500 (mm)
|
|
Working temperature
|
-10℃~+55℃
|
To be an international, standardized and sustainable corporation is our consistent pursuit. We sincerely welcome customers from home and abroad to visit our company.