Introduction
T3000 PRO is a high performance underground metallic pipe locating system. It consists a transmitter and a receiver, can be used to do route tracing, pipe exploration and depth measurement of the underground cables and metallic pipes. It can also be used to identify target cable from a bunch of cables, locate the pipe insulation damage and part type cable fault.
Transmitter
|
|
Output
|
Direct Connection output, Clamp Coupling Output(optional), Radiation output
|
Output Frequency
|
640Hz (Fault finding booster optional), 1280Hz (complex frequency), 10kHz, 33kHz,82kHz, 197kHz
|
Output power
|
Max. 10W, 10 levels adjustable, auto impedance matching
|
Direct connection voltage
|
Max. 150Vpp
|
HMI
|
320 X 240 (mm) LCD
|
Power supply
|
4*built-in 18650 Li-on batteries, standard 7.4V, 6.8Ah
|
Receiver
|
|
Input
|
Internal receiving loop, Clamp (optional), sensor (optional), fault locating A Frame (optional)
|
Receiving frequency
|
Active detection frequency: 640Hz, 1280Hz, 10kHz, 33kHz, 82kHz, 197kHz.
Power frequency passive detection frequency: 50Hz/60Hz and 250Hz/300Hz (user configurable). Radio frequency passive detection frequency bands: center frequencies are 10kHz, 33kHz, 82kHz, respectively |
Pipe detection mode
|
Wide peak method, narrow peak method, valley method
|
Cable identification mode
|
Receiving Clamp (optional) intelligent identification and sensor (optional) identification
|
HMI
|
320 X 240 (mm) LCD
|
Others
|
|
Volume
|
Transmitter: 280 X 220 X 90 (mm)
Receiver: 680 X 277 X 120 (mm) |
Weight
|
Transmitter: 2.3kg
Receiver: 2kg |
Charger
|
Input: AC 100-240V, 50/60Hz
Output: DC8.4V, 2A |
Working environment
|
Temperature: -10-40℃
Humidity: 5-90% Elevation: <4500m |
To be an international, standardized and sustainable corporation is our consistent pursuit. We sincerely welcome customers from home and abroad to visit our company.